Check Point 61000 Instrukcja Obsługi Strona 38

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 47
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 37
Showing Chassis and Component Status (asg monitor)
Parameter
Description
interval
Monitors SGM state and running processes. Enter a
decimal value in seconds, for example: asg monitor
3
-v interval
Monitors chassis parameters. For example: asg
monitor v 3.
-all interval
Monitors all SGMs and chassis parameters
Example 1
asg monitor
Output
Comments
This shows:
The date and time when information was last collected
Chassis 1 is ACTIVE with three Security Gateway Modules up
Chassis 2 is in STANDBY state with three Security Gateway Modules up
Security GW State is the state of the Security Gateway Module. The state can
be
Up
Down
Detached.
A state can have one of these Processes:
Enforcing Security - The SGM is UP and working properly.
Inactive - The SGM is DOWN, and is experiencing some problem. It is
not handling any traffic.
Initial policy - The policy is not installed on the SGM.
To manually change the state of an SGM, use the asg_blade_admin
command. Remember that this command administratively changes the state
to up or down. An SGM physically down can not be changed to UP using this
command.
(local) - represents the SGM on which you ran the command.
Example 2
asg monitor -v
Przeglądanie stron 37